Medical device consultancy, grounded in engineering.

Medical device regulations are complex.Implementing them shouldn't be.

Practical regulatory, quality and software compliance consultancy, grounded in real engineering and product development experience.

Requirements traced through engineering to evidenceIllustrative. Four requirements each traced through engineering to evidence: MDR Annex I section 17 to software requirements to a traceability matrix; ISO 13485 section 7.3 to architecture and design to design review records; IEC 62304 section 5.7 to verification to test reports; ISO 14971 section 7 to risk controls to the risk management file. The last link, from risk controls to the risk management file, is missing and shown as a gap.REQUIREMENTENGINEERINGEVIDENCEMDRAnnex I §17SoftwarerequirementsTraceabilitymatrixISO 13485§7.3Architecture& designDesign reviewrecordsIEC 62304§5.7VerificationTest reportsISO 14971§7Risk controlsRisk managementfileGap: no evidenceIllustrative: each requirement traces throughengineering to evidence; a missing link shows as a gap.
Requirements traced through engineering to evidenceIllustrative. Four requirements each traced through engineering to evidence: MDR Annex I section 17 to software requirements to a traceability matrix; ISO 13485 section 7.3 to architecture and design to design review records; IEC 62304 section 5.7 to verification to test reports; ISO 14971 section 7 to risk controls to the risk management file. The last link, from risk controls to the risk management file, is missing and shown as a gap.REQUIREMENTENGINEERINGEVIDENCEMDRAnnex I §17SoftwarerequirementsTraceabilitymatrixISO 13485§7.3Architecture& designDesign reviewrecordsIEC 62304§5.7VerificationTest reportsISO 14971§7Risk controlsRiskmanagementfileGapIllustrative: each requirement traces throughengineering to evidence; a missing linkshows as a gap.

How we help

Where are you with your device?

One quality system, two regulatory routesIllustrative. Two routes, EU MDR (classify, assess, CE mark) and FDA (classify, submit via 510(k), De Novo or PMA, register), both supported by shared risk management (ISO 14971), software lifecycle (IEC 62304) and technical and clinical documentation, on a foundation of an ISO 13485 quality system (FDA QMSR, EU MDR Article 10(9)).EU MDRCE marking route1ClassifyAnnex VIII,Rule 112AssessSelf-declare, orNotified Body3CE markCE marking, UDI,EUDAMEDFDAMarket authorisation1ClassifyClass I, II or III,product code2Submit510(k), De Novoor PMA3RegisterEstablishment,listing and UDIRisk managementISO 14971SoftwareIEC 62304DocumentationTech, clinicalISO 13485 quality systemFDA QMSR · EU MDR Art. 10(9)Illustrative. The route depends on device class.

Regulatory & Quality Consulting

Developing a new medical device

Settle intended purpose, classification and regulatory route, then put the quality system and documentation in place.

Explore Regulatory & Quality
IEC 62304 software development activities, one possible arrangementIEC 62304 activities 5.1 to 5.8 shown as one possible arrangement: development planning, requirements analysis, architectural design, detailed design, unit implementation and verification, integration and testing, system testing, release, then software maintenance (clause 6). Cross-cutting throughout: clause 7 risk management, clause 8 configuration management, clause 9 problem resolution. The standard does not prescribe a lifecycle model.IEC 62304 · one possible arrangement5.1Development planning5.2Requirements analysis5.3Architectural design5.4Detailed design5.5Unit implementation & verification5.6Integration & testing5.7System testing5.8ReleaseCl. 6Software maintenanceCROSS-CUTTING THROUGHOUTCl. 7 Risk managementCl. 8 Configuration managementCl. 9 Problem resolution

Medical Device Software Compliance

Developing or maintaining regulated software

IEC 62304 lifecycle processes, risk management, verification and release practices your engineers can follow and your documentation can evidence.

Explore Software Compliance
Illustrative readiness coverageIllustrative coverage, not a client result. Five requirement areas against ISO 13485, EU MDR, FDA and IEC 62304: most areas evidenced; gaps shown for EU MDR technical documentation and IEC 62304 software lifecycle; IEC 62304 not applicable to quality system and post-market. Steps: assess, identify gaps, remediate, reassess, repeating until ready for review. Vera-supported where appropriate.ISO13485EUMDRFDAIEC62304Quality systemRisk managementSoftware lifecycle!Technicaldocumentation!Post-marketEvidencedGapNot applicable1Assess2Identify gaps3Remediate4ReassessVera-supported where appropriateIllustrative coverage, not a client result

Regulatory Readiness & Remediation

Preparing for an audit, submission or milestone

Independent assessment of your documentation and evidence, a prioritised plan, and help closing the gaps.

Explore Readiness & Remediation

Why MediLife

Practical expertise, backed by evidence.

Regulatory and quality expertise

EU MDR, UK and FDA requirements, ISO 13485 quality systems and technical documentation, from classification to post-market.

Led regulatory strategy for a professional services firm's digital health venture, securing MHRA registration for its clinical decision support system and bringing its referral management product to the UK market.

Real engineering and product experience

We know how regulated software is developed, verified, released and maintained, so requirements become processes your team can run.

Conducted a year-long review of a life-sciences instrumentation company's software development processes and rewrote its software quality management system end to end.

Vera-supported assessment and remediation

Structured, repeatable analysis of your documentation against applicable requirements, reviewed by our specialists, then practical help closing the gaps.

Vera · AssessmentIllustrative sample, not a client result

Requirement

Supporting evidence

No formally documented, implemented QMS evidence found for this clause.

Identified finding

Requirement not evidenced

High

Recommended remediation

Establish and document QMS procedure covering §4.1 scope.

Illustrative sample. Vera supports our specialists' judgement; it does not certify compliance or guarantee approval.

How Vera works

Let's talk about your device.

The first step is a short introductory conversation. Tell us what's coming up, whether that's an audit, a submission, a software release or a first regulatory plan, and we'll tell you how we can help.

Talk to a Specialist